Home About us Editorial board Ahead of print Current issue Search Archives Submit article Instructions Subscribe Contacts Login 
  • Users Online: 767
  • Home
  • Print this page
  • Email this page
ORIGINAL ARTICLE
Year : 2017  |  Volume : 3  |  Issue : 1  |  Page : 4-10

Evaluation of hardness and degree of conversion of different bulk-fill materials cured with Quartz Tungsten Halogen and light emitting diode devices


Department of Conservative Dentistry and Endodontics, Government Dental College and Hospital, Patiala, Punjab, India

Correspondence Address:
Ashok Suman
Department of Conservative Dentistry and Endodontics, Government Dental College and Hospital, Patiala, Punjab
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/sidj.sidj_2_18

Rights and Permissions

Aims: The aim of this study is to evaluate the hardness and degree of conversion (DC) of different bulk-fill materials when cured with the Quartz Tungsten Halogen (QTH) and Light emitting diode (LED) devices using same energy density. Settings and Design: This was in vitro study. Materials and Methods: Three different bulk-fill materials, i.e., Filtek™ [3M ESPE], Tetric® N-Ceram [Ivoclar Vivadent], and SDR (Smart Dentin Replacement) by Dentsply Caulk, were used for making 180 samples (60 samples each) in Teflon mold. Out of these 60 samples, samples of three heights were prepared, i.e., 2 mm, 4 mm, and 6 mm (20 each). All the sample molds were filled in single increment and were exposed to the QTH and LED using the same energy density. Then, these samples were tested for microhardness using the Vickers hardness (VH) testing machine (Mitutoyo, Japan) and DC using Fourier Transform Infrared Spectroscope (Cary 630 FTIR Agilent Technologies, Germany). Statistical Analysis Used: The statistical analysis was performed on the collected data. The Kolmogorov–Smirnov and Shapiro–Wilk tests showed that the data are normally distributed. Since all the variables were continuous and statistically independent, independent t-test was applied to compare mean values of VH and DC of inter groups. Results: The statistical analysis of readings revealed that there was no significant difference in the mean values of microhardness and % DC for both groups cured by QTH and LED. Conclusions: It can be concluded that irrespective of the type of the light cure unit if the energy density applied is same then almost similar performance can be expected from the devices.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed8405    
    Printed834    
    Emailed0    
    PDF Downloaded239    
    Comments [Add]    

Recommend this journal